MM-100 Metabolic Monitor System

The MM-100 Metabolic Monitor is a complete system for measuring oxygen consumption in the small animal. 1 to 16 animals can be measured. Using the latest technology in paramagnetic O2, infrared CO2, and thermal mass flowmeter analyzers, it automatically computes O2 consumption, CO2 production, and respiratory exchange ratios (RER).

MM-100 Metabolic Monitor System

Simple set up and operation: The animal is placed in the provided chamber and allowed to equilibrate for 5 - 10 minutes. All gas and flow measurements, and computed results are shown on the front panel LCD display panel. A serial port connection sends the measurements to any attached computer. Using the included WindowsTM software, the readings for O2 consumption and CO2 production, along with their moving time averages, are plotted. Data can be logged to simple ASCII files for further analysis. Standardization against room air is automatically performed at intervals, so the accuracy of the system is maintained for long intervals of monitoring.

Multiple chamber systems: Expansion to multiple animals is straightforward. Using the MMX-4 or MMX-16 (for four and sixteen animals, respectively) expansion units, gas sampling and measurement is automatically sequenced between the chambers. This results in an accurate, economical system for screening large numbers of animals for these important physiological parameters.

MM-COMM Monitoring Software: Each MM-100 system includes Windows software for graphically displaying and logging the metabolic data. This software provides a Data Panel showing all the current raw and computed measurements. Data is logged in a simple ASCII format for directly importing it into a spreadsheet or other analysis program. Each resord is tagged with the animal number and time of the measurement.

Complete package: The MM-100 comes complete with all necessary components for a single-chamber measurement. This includes the main MM-100 unit, small animal chamber, air pump, drying tubes, and required tubing. The only consumable item is the Drierite material for drying the gas sample.

One year warranty
120/240V
CE

Part #

Description

11-20000 MM-1000

Metabolic Monitor system with mouse chamber Measure O2 consumption, CO2 production

11-22000 MMX-2

Two-chamber expansion unit w/ 2 chambers Monitor two animals simultaneously

11-23000 MMX-8

Eight-chamber expansion unit w/ 8 chambers Monitor eight animals simultaneously

11-24000 MMX-16

Sixteen-chamber expansion unit w/ 16 chambers Monitor sixteen animals simultaneously

11-20100

Mouse cage Measurement chamber, approx. 1 liter For mice and similar size animals

11-20110

Rat cage Measurement chamber, approx. 2.5 liter For rats and similar size animals

11-20200

Drying tube Spare Drierite tube, pk of 4 Can be regenerated by oven heating

11-20210

Drying column Large dessicant column, 6.7cmD x 29cmH For long-term monitoring

11-20211

Dessicant Bulk Drierite dessicant, 12 1 lb packs Refill for drying tubes or columns



IITC Life Science Inc.
23924 Victory Blvd Woodland Hills, CA 91367
818 710 8843 fax 818 992 5185
 
Copyright (c) 2009. IITC Life Science
All rights reserved.